Skip to main content

medi® pcs genius

The medi® pcs genius is a premium pneumatic compression system used primarily in the treatment of lymphedema in the legs and arms.
 

medi® USA

medi® USA is a medical product and technology company focused on compression therapies for chronic medical conditions, athletic performance, and fashion. The medi product family continues to innovate, leading the way in modern compression therapy that improves the quality of life for every patient across all stages of venous and lymphatic conditions.
Toll free:(800) 633-6334 Fax:(888) 570-4554 Website: www.mediusa.com
Benefits

• Simple Preset Treatment program selection available
• 6 to 20 chamber outputs for customized therapy
• Plug and play, for ease of patient use
• Choice of primary treatment modes
• Customize compression setting for each individual chamber
• Focus therapy settings for targeted treatment
• Optional decongest mode to clear proximal pathways prior to initiating full treatment
• Unilateral and bilateral treatment combinations
• Upper and lower extremity garments available in multiple sizes and lengths

Indications

The medi® pneumatic compression system (pcs) genius is a compression device based on sequential pneumatic compression technique which is intended for the treatment of the following conditions: lymphedema; venous stasis ulcers; venous insufficiency; peripheral edema. The device is intended for home and hospital use. 

Contraindications

Absolute Contraindications: use while ambulatory; use while sleeping; the presence of  lymphangiosarcoma; suspected or known acute deep vein thrombosis; existing pulmonary edema; existing pulmonary embolism; inflammatory phlebitis; severe congestive cardiac failure; severe atherosclerosis or other ischemic vascular diseases; any circumstance where increased venous and lymphatic return is undesirable; extreme musculoskeletal deformity of limb intended for treatment; any local skin or tissue condition which the device would interfere such as gangrene, untreated or infected wounds, recent skin graft, and dermatitis; known presence of malignancy in the limb intended for treatment; limb infections, including cellulitis, that have not received antibiotic coverage. 
Relative Contraindications: unsupervised children use under the age of 18; allergy or intolerance to garment material (100% Nylon) 
Caution should be used when treating patients with heart disease or peripheral occlusion disease as the increased movement of fluids may pose additional health risks.

Warnings and Precautions

Warning: Explosion Hazard
Do not use in the presence of flammable gases, including flammable anesthetics.
Warning: Electrical Shock Hazard
Do not allow liquid to enter any part of the system.
Warning: Electric Shock Hazard
Never attempt to perform maintenance or service the device while in use. To completely eliminate power, disconnect the power supply from the Pressure Control Unit or from the wall outlet.
Warning: Electric Shock Hazard
Unplug power supply from source and do not use medi® pcs during electrical storms.
Warning: Electric Shock Hazard
To prevent electric shock, do not open the Pressure Control Unit. Do not attempt to service the pressure control unit yourself. All maintenance tasks should be performed only by the manufacturer or by authorized service personnel.
Service by unauthorized personnel shall void the warranty.
Warning: Ventilation Hazards
Always place the pump on a solid surface free of objects that may block ventilation openings. Never lock the ventilation openings. Keep the ventilation opening free of debris such as lint and hair. Never operate the pump on a soft surface, such as a bed, couch, or pillow, where the ventilation opening may be blocked. Never drop or insert any object into any opening of the pump.
Warning: Environmental Hazards
Keep the pump, garments, and power supply cord and plug away from sharp objects, flames, and heated surfaces.
Warning: Proper Inspection Required
Prior to using always inspect pressure control unit, power supply, garments, and connectors for damage.
Warning: Tripping
Never operate the controller where the cord or tubing harness shall present a tripping hazard.
Warning: Strangulation
The power supply and hoses of this product may pose a strangulation hazard. Keep power supply and hoses out of the reach of children at all times.
Warning: Contact Injuries
Pressure Control Unit should be placed at same height or below patient to prevent possible injury from device falling on patient.
Warning: Treatment Should Never Hurt
The garment compression should never hurt. If you experience pain or notice your condition worsening, contact your physician. Do not change your treatment settings without consulting your physician.
Warning: Parental Supervision
Children under the age of 18 should only use the system under adult supervision and direction of a physician.
Caution: Single Patient Use
Garments are intended for single patient non-ambulatory use only.
Caution: Compatibility
Use only the medi® pcs power supply (GSM60B24), garments, and accessories with the medi® pcs system.
 

Storage Requirements

After treatment is complete and the Pressure Control Unit (PCU) is turned off, unplug the power supply cord from the power outlet and from the PCU. Disconnect the garments from the PCU. Store the garments by first loosely coiling the hoses and garment connectors. Avoid kinking or crushing the hoses. Lay the garments flat in a cool, dry place for storage. Store the PCU in a cool, dry place, avoiding direct sunlight. Keep it away from excessive heat or cold, and keep away from children and pets.
 

How Supplied/Sizing
Upper and lower extremity garments available in multiple sizes and lengths. 6-20 chambers.
HCPCS Code
Product features
cancel 120mmHg inflation available
cancel Adjustable air bladders
cancel Automatic shut-off
check_circle Half/full sleeves
check_circle LCD display
check_circle Leg/arm sleeves
cancel Low-pressure alert light
cancel Non-peristaltic sequential compression
check_circle Peristaltic gradient sequential compression
cancel Pressure gauge
cancel Pressure regulator dial
check_circle Programmable
check_circle Timed cycle inflation/deflation
check_circle Velcro® on sleeve
cancel Zipper on sleeve
Other features
check_circle Educational Material Available
check_circle Free Samples/Trials Available
cancel Published Clinical Article Available
Recommended Use

Chronic Wounds
Venous Ulcers
 

Mode of Use/Application

Leg:
Loosely form the garment to your leg's shape and fasten the hook tabs. With the foot piece of the garment furthest from you, slide your leg into the garment until it reaches your knee (for lower leg) or upper thigh (for whole leg). Note: do not stand or walk while wearing leg garments. Photo is for illustration purposes only. eadjust the hook and loop material of the garment if necessary so that it fits securely but comfortably on your leg. As the garment inflates it will intelligently apply compression based on your limb size so it is not necessary that the garment have a snug fit or apply compression from donning. Continue securing the garment up your leg until the entire garment is fastened. When applied, the garment should be comfortably secured, but not so tight that it applies compression. Fully applied whole leg shown in. Note: Do not stand or walk while wearing leg garments. Your toes may or may not extend from the end of the garment, depending on your foot size. The garment should not be applied so tightly that it applies compression without inflation, and it should never hurt. The garment connector should extend from the end of the garment closest to the heel.
Arm:
Loosely form the garment to your arm's shape and fasten the hook tabs. Use the outermost hook panel for larger circumference arms. Fold the panel under itself and use the inner hook panel for smaller circumference arms. With the curved end of the garment closest to you, slide your arm into the garment until it reaches your armpit. Ensure that the curved top edge of the garment is positioned on the outer side of your shoulder. The straight end of the garment should be positioned over the hand. Readjust the hook and loop material of the garment, if necessary, so that it fits securely but comfortably on your arm. As the garment inflates it will intelligently apply compression based on your limb size so it is not necessary that the garment have a snug fit or apply compression from donning. Your fingers may or may not extend from the end of the garment depending on the length of your arm. When applied, the garment should not be so tight that it applies compression and it should never hurt. The garment connector should extend from the end of the garment closest to the wrist.
 

Removal & Change Frequency

Disconnect the garment from the PCU and deflate as necessary. To remove the garment, either slide your limb out of the garment or undo the hook and loop material and remove your limb. It is recommended to keep the hook and loop material fastened even when the compression garment is not in use to avoid it snagging on clothes, linens, or other materials. 

Construction

Sleeves are 100% nylon.

Warranty

The Manufacturer's Warranty states that products are warranted to be free from defects in material and workmanship for a defined period. The Manufacturer's sole obligation in the event of a breach of this warranty is expressly limited to the replacement of defective parts that, in the sole discretion of the Manufacturer, cannot be repaired. Replacement parts may be new or refurbished parts as solely determined by the Manufacturer. This warranty is available only to the original user and is not transferable. Repairs or alterations to the product not conducted by the Manufacturer shall void these warranties. These warranties do not cover failures due to improper or negligent use of the product. The Pressure Control Unit (PCU) is covered by warranty for 3 years. The garments are covered by warranty for 1 year. 
For questions regarding the Manufacturer's Warranty and technical support, please contact the authorized reseller from the point of purchase. 
 

Clinically Tested

CHG-compatible
Latex-friendly
Non-allergenic
Non-comedogenic
Non-cytotoxic
Non-irritating

Technical Specifications

MODEL: genius 
IEC PROTECTION CLASSIFICATION: Class II 
DIMENSION: 8.75" (W) x 13" (D) × 4.5" (H) 
WEIGHT: 6.6 lbs 
PRESSURE RANGE: 20-100 mmHg 
ELECTRICAL: 100 - 240vac, 50/60Hz, 1.4 -0 .7 amps 
POWER: 60 Watts 
IP2X: Protected against ingress of solid objects over 12.5 mm e.g. accidental touch by a person's hand. 
No protection against ingress of liquids. 
APPLIED PART: Type BF 
APPLIED STANDARDS: ANSI/AAMI ES60601-1, AAMI HA60601-1-11, CSA C22.2 No. 60601-1, CSA C22.2 No. 60601-1-11, 
ISO 13485, ISO 14971, IEC 62304 IEC/EN 60601-1-2, IEC/EN61000-3-2, IEC/EN 61000-3-3, FCC CFR 47; Part15; Subpart B, ICES 001; ISSUE 4, AS/NZS CISPR 11, JIS T 0601-1-2, ABNT NBR IEC 60601-1-2 
LEGAL MANUFACTURER: medi USA, LP, 6481 Franz Warner Parkway, Whitsett, NC 27377, www.mediusa.com Made in USA
 

No posters match your selected filters. Remove some filtres, or reset them and start again.

Have a product to submit?

Be included in the most comprehensive wound care products directory
and online database.